PHP Notice
Undefined index: header_background_ltd.jpg


PHP Warning
Cannot modify header information - headers already sent by (output started at [SYSTEM_ROOT]/core/include/general.inc:167)

Analytical Chemistry
Print

Analytical Chemistry

The analytical chemistry team provides a range of high quality analytical services for both research and commercial projects.

The radioanalytical and analytical laboratories support various studies such as low level tritium analysis in aqueous samples, trace metal analysis in aquatic environments, measurement of naturally occuring radioacitve material (NORM), pollutant transport in groundwater and emission of volatile and wastes chemicals in the environment.

Facilities

The laboratories are equipped with sophisticated instrumentation such as: quadrupole inductively coupled plasma - mass spectrometer (ICPMS); a simultaneous inductively coupled plasma atomic emission spectrometer (ICPAES); a gas chromatograph mass spectrometer (GCMS); a liquid chromatograph mass spectrometer (LCMS), a carbon, nitrogen and sulphur analyser (CNS), anion & cation chromatographs (IC) and isotope ratio mass spectrometer (IRMS)

MLS 1200 Mega laboratory microwave digester


MLS1200 Mega laboratory microwave digester with pressure and temperature control system. Sample digestion is performed using acids under temperature controlled conditions.

Inductively Coupled Plasma - Mass Spectrometer, ICP-MS

The HP4500 Inductively Coupled Plasma - Mass Spectrometer (ICP-MS) is capable of measuring trace elements at levels as low as one part per trillion.

Inductively Coupled Plasma Atomic Emission Spectrometer, ICP-AES

Vista Simultaneous Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) is an axially viewed instrument with purged echelle polychromator and VistaChip image-mapped Charged Coupled Device (CCD) detector.

IsoPrime Isotope Ratio Mass Spectrometer, IRMS

IsoPrime Isotope Ratio Mass Spectrometer (IRMS) with EuroVector Pyr-OH elemental analyser capable of determining δ 18O & δ 2H ratios for studies into water resources.

 Varian CP-3800 Gas Chromatograph

Varian CP-3800 Gas Chromatograph. ML1220 Mass Spectrometer (GCMS) for Perfluorocarbons (PFC) analysis at levels as low as parts per trillion.

liquid chromatography analysis

The Liquid Chromatograph Mass Spectrometer (LCMS) is used to monitor human exposure to uranium.

ANSTO projects & business units that use the analytical chemistry facilities:

Research Applications of our capabilities:

Examples of where our analytical and radioanalytical facilities have been used in environmental research can be seen in the following past research projects

For more information contact:

Mr Henri Wong
E-mail